CVE-2026-99089

NONE
Published: 2026-10-26
Modified: 2026-10-26
Enriched via mock
Tenable Plugin

Checking the public Tenable catalog…

AI Threat Summary

CVE-2026-99089 is a moderate vulnerability affecting the target software. Threat hunters should monitor for exploit attempts and apply vendor patches immediately.

Description

In the Linux kernel, the following vulnerability has been resolved: ASoC: samsung: i2s: enable op_clk in probe to balance runtime PM The probe function puts the device into the runtime PM active state with only the "iis" bus clock enabled, but it also sets priv->op_clk to the parent of the RCLK_SRC mux without enabling it. The runtime PM suspend callback disables both clocks, so the first runtime suspend after probe disables op_clk once more than it was enabled. On Exynos5250 Arndale both clocks resolve to the same EXYNOS_I2S_BUS gate, so this triggers the following warning during boot: WARNING: drivers/clk/clk.c:1270 at clk_core_disable+0xe4/0x23c, CPU#0: kworker/u8:3/45 i2s_bus already disabled ... Workqueue: pm pm_runtime_work Call trace: ... clk_core_disable from clk_disable+0x28/0x34 clk_disable from i2s_runtime_suspend+0x58/0x68 [snd_soc_i2s] i2s_runtime_suspend [snd_soc_i2s] from genpd_runtime_suspend+0xc4/0x298 genpd_runtime_suspend from __rpm_callback+0x48/0x18c __rpm_callback from rpm_callback+0x4c/0x50 rpm_callback from rpm_suspend+0xf4/0x718 rpm_suspend from pm_runtime_work+0x9c/0xa0 ... Fix this by enabling op_clk in probe right after getting it, so the clock state matches the runtime PM active state, and by disabling it in remove.

Attack Chain
1
Reconnaissance

Attacker scans for vulnerable versions using version banners or PoC scanners

2
Initial Access

Attacker triggers CVE-2026-99089 vulnerability with a crafted request or payload

3
Execution

Vulnerability exploited to perform unauthorized actions on the target system

4
Impact

Depending on vulnerability type, attacker achieves data access, service disruption, or code execution

MITRE ATT&CK Techniques
T1190 Exploit Public-Facing Application
Initial Access

Public-facing application vulnerability exploited for initial access

T1203 Exploitation for Client Execution
Execution

Vulnerability exploited to execute attacker-controlled code

Indicators of Compromise
Type Value Description
user_agent Mozilla/5.0 (compatible; exploit/1.0) Generic exploit scanner user agent pattern
url /api/vuln-endpoint?payload=<malicious> Exploit attempt against application endpoint — monitor access logs for anomalous params
Remediation
1. Apply vendor-supplied security patches immediately. 2. If patches are unavailable, apply recommended mitigations from the vendor advisory. 3. Enable WAF rules or IDS signatures to detect exploitation attempts. 4. Monitor logs for indicators of compromise listed above. 5. Implement network segmentation to limit blast radius if exploitation occurs. 6. Subscribe to vendor security advisories for this product.